Tent Heater Calculator: BTUs, Heaters and Fuel for Event Tents

Enter your tent's size and heights, the outside and target temperatures, how closed in the tent is and the heater you're renting. Get the BTUs per hour to heat it, how many heaters you need, and how much propane or diesel to order for the event. A planning estimate to take to your heater supplier.

Size the Heat for Your Event Tent

Tent size

Height at the eaves, where the sidewalls hang.

Height at the center. On the tent's spec sheet.

Temperatures and enclosure

The coldest you expect while heating. Negative is fine.

Coats-on comfort for a market is often lower than a dinner.

All sidewalls down on bare ground or grass, doors opening often.

Rule of thumb from the enclosure. Use your supplier's if they give one.

Heaters and fuel

Per heater, BTU/hr burned. For example 150,000 or 170,000.

Share delivered as heat. Check the spec sheet.

About 91,500 BTU per gallon (approximate).

Preheat included.

218,400 BTU/hr

Heat needed

To warm 31,200 cubic feet by 35°F at a 0.2 factor.

2

Heaters needed

240,000 BTU/hr delivered together.

3.3 gal

Fuel per hour

Propane, all heaters at full fire.

98.4 gal

Fuel for the event

Over 30 heating hours.

How the tent heating estimate is built up
Floor area2,400 sq ft
Average height13 ft
Tent volume31,200 cu ft
Temperature rise35°F
Heat from each heater120,000 BTU/hr

The formula

Length × width × (sidewall + peak) ÷ 2 = tent volume.
Volume × temperature rise × heat-loss factor = BTU per hour.
BTU per hour ÷ (heater rating × efficiency), rounded up = heaters.
Heaters × rating ÷ BTU per gallon × hours = fuel.

Rough planning estimate, not safety or code advice. The factors are rules of thumb. Use indirect-fired, vented heaters with the burner outside for an occupied tent; your heater supplier sizes and places them and the fire marshal approves the setup. Build heating into your event safety plan and ask the tent company the questions to ask a tent rental company about heating and sidewalls.

How the Tent Heater Calculator Works

  1. 1. Work out the tent’s volume

    Multiply length by width by the average of the sidewall and peak heights. A 40 x 60 ft tent with 8 ft sidewalls and an 18 ft peak holds 31,200 cubic feet. Not sure of the size yet? Start with the event tent size calculator.

  2. 2. Set the temperature rise

    Subtract the coldest outside temperature you expect from the temperature you want inside. A winter market where shoppers keep coats on can aim lower than a seated dinner.

  3. 3. Pick how closed in the tent is

    Sidewalls, a floor and closed doors hold heat; open sides let it blow away. The factor turns volume and temperature rise into BTUs per hour.

  4. 4. Count heaters

    Divide the heat needed by what one heater delivers (its rating times its efficiency) and round up. Spread several smaller heaters around a long tent rather than relying on one big unit.

  5. 5. Order fuel and power

    Fuel is planned at full fire for every heating hour, so it is a ceiling. Most indirect-fired heaters also need electricity for the fan and controls; add them to the event power calculator along with vendor and lighting loads.

Heating is a safety item, not just a comfort one. Put heater positions, fuel storage, clearances and carbon monoxide checks in your event safety plan, and confirm sidewalls, flooring and heater placement with the questions to ask a tent rental company.

Enclosure Factors Used

Rough planning rules of thumb, in BTU per hour per cubic foot per degree F. They are not a standard or a test result: your heater supplier sizes the real system and the fire marshal approves it.

Tent enclosure types and the heat-loss factor used for each
EnclosureFactor
Sidewalls plus floor or linerAll sidewalls down, with a floor or liner and doors kept closed.0.133
Sidewalls, no floorAll sidewalls down on bare ground or grass, doors opening often.0.2
Open or partly open sidesOpen or partly open sides. Spot heat only: the tent may never reach the target.0.4

Indirect-Fired Heaters for Occupied Tents

For a tent with people in it, plan on indirect-fired, vented heaters: the burner and fuel sit outside and a duct brings warm, clean air in while the exhaust vents away. Direct-fired and unvented heaters release combustion gases into the space. Ask the supplier about thermostats, ducting, fuel tank placement and refills, and ask the fire marshal what permit or inspection applies. This is not safety or code advice.

Map Tents, Heaters and Vendor Spaces with Map D

Map D doesn’t size heaters or replace your supplier’s plan. It helps you lay out the site around them: in Map D’s floor plan editor you can set the map to your site’s size, mark each tent with a rectangle area, and place vendor booths, aisles and named areas for heater and fuel tank positions, all drawn to scale. Running a holiday market or winter festival? Our festival management software puts vendor spaces on the same map, and any site plan starts in our event floor plan software. You can build one event’s floor plan free; publishing it needs a paid plan, from $1,500 per event.

Heat Needed for Common Tent Sizes

Each size at this calculator’s defaults: a 35°F rise (30°F outside to 65°F inside), sidewalls with no floor (0.2) and 150,000 BTU/hr heaters delivering about 120,000 each. Heights are examples with an 8 ft sidewall; use your tent’s spec sheet and the calculator above for your own figures.

Estimated heat and heaters needed by common tent size
Tent sizeExample peakVolume, cu ftBTU/hrHeaters
20 x 20 ft12 ft4,00028,0001
20 x 40 ft13 ft8,40058,8001
30 x 30 ft15 ft10,35072,4501
30 x 60 ft16 ft21,600151,2002
40 x 60 ft18 ft31,200218,4002
40 x 80 ft18 ft41,600291,2003
60 x 100 ft22 ft90,000630,0006

What this assumes

Every figure the calculator starts with, and where it comes from. Where the honest answer is that a number depends on your venue, it says so rather than inventing one.

Tent volume
Length x width x the average of the sidewall and peak heights, in cubic feet. The default 40 x 60 ft tent with 8 ft sidewalls and an 18 ft peak is an example; take the real heights from the rental company's spec sheet. Heat rises, so a tall peak adds volume you pay to heat.
Temperature rise
Target inside temperature minus the coldest outside temperature you expect while the tent is open. Defaults are 30 F outside and 65 F inside, a 35 F rise. Use the overnight low if the heaters run before doors open, and plan for wind on top.
Enclosure (heat-loss) factor
A rule-of-thumb factor for how fast warm air escapes, in BTU per hour per cubic foot per degree: 0.133 closed up with sidewalls and a floor or liner, 0.2 with sidewalls on bare ground (the default) and 0.4 with open or partly open sides. They are this calculator's planning figures, not a standard or a test; type your supplier's factor if they give you one.
Heater rating and efficiency
Each heater's rating in BTU per hour of fuel burned (150,000 by default, for example; 170,000 is another size you'll see) and the share delivered into the tent as heat (default 80%). Check the supplier's spec sheet: some list input and output separately.
Fuel
All heaters at full fire for every heating hour, the most they can burn: 10 hours a day for 3 days by default, preheat included. Propane holds about 91,500 BTU per gallon and diesel or heating oil about 138,500 (approximate heating values). Thermostats cycle the heaters, so actual use is usually lower.

What it does not model

  • Safety and permits. This is not safety or code advice. Occupied tents should be heated with indirect-fired, vented heaters with the burner and fuel outside the tent, placed and ducted by the supplier. The fire marshal or local authority may require a permit, inspection, clearances and fuel-storage rules; ask before you book.
  • Wind, rain and snow. Wind strips heat from tent fabric fast, and snow load is a structural question for the tent company, not a heating one.
  • Doors and traffic. A market or festival tent with doors open all day behaves closer to the open-sides factor than the sidewalls one.
  • People, lights and cooking. A packed tent warms itself, and food vendors add heat (and ventilation needs). The calculator ignores both, which errs on the warm side.
  • Electrical power. Most indirect-fired heaters need power for the fan and controls; add them to your generator or power plan.

Estimate only, from the figures you entered. Not a quote. Last reviewed November 2026.

See it on your own floor plan

Stop reading about it. Build one.

Upload the floor plan you already have and place your booths on it yourself, in Map D’s editor. Free to build, no contract, and nothing to install.

900+
Organizers who have run shows on Map D
9,000+
Events powered since 2011
1.8M+
Booths drawn to date

“I am really excited about this. The staff met with me this morning and we all LOVE the platform. People are already filling out their booths.”

· Director, International Trade and Development @ Maine Insurance Agents Association

Frequently asked questions

How many BTU does it take to heat a tent?

Multiply the tent's volume in cubic feet by the temperature rise you need and a heat-loss factor for how closed in the tent is. At this calculator's defaults, a 40 x 60 ft tent with an 8 ft sidewall and 18 ft peak (31,200 cubic feet), warmed 35 F with sidewalls down at a 0.2 factor, needs about 218,400 BTU per hour. Fully closed with a floor (0.133) it is about 145,000; with open sides (0.4) about 437,000.

How many heaters do I need for a 40x60 tent?

At this calculator's defaults, 2 heaters rated 150,000 BTU/hr: the tent needs about 218,400 BTU per hour and each heater delivers about 120,000 at 80% efficiency. On a colder day, with open sides or a taller peak you may need 3 or 4. Ask your supplier whether to add a spare in case one fails.

How much fuel does a tent heater use?

Two heaters rated 150,000 BTU/hr burn about 3.3 gallons of propane an hour between them at full fire (2 x 150,000 / about 91,500 BTU per gallon), or about 2.2 gallons of diesel. Over 10 hours a day for 3 days that is about 98 gallons of propane or 65 of diesel. Thermostats cycle the heaters, so this is a ceiling to order against; the supplier confirms tank sizes and refills.

What kind of heater should I use in an event tent?

For a tent with people inside, plan on indirect-fired heaters: the burner sits outside and ducts warm, clean air in, while the exhaust vents outside. Direct-fired and unvented heaters put combustion gases into the space. The heater supplier and the fire marshal decide what is allowed and where it goes.

Can I plan tents and heaters on the site map in Map D?

Yes, for the layout. In Map D's floor plan editor you can set the map to your site's size, mark each tent with a rectangle area and lay out vendor booths, aisles and named areas for heater and fuel tank positions, all drawn to scale. Map D doesn't size heaters or replace your supplier's plan. You can build one event's floor plan free; publishing it needs a paid plan, from $1,500 per event.