Skip to main content
Free organizer tool

Event Power Calculator: How Big a Generator Do I Need?

Count the vendor booths, food vendors, food trucks, stages and lights on your supply, check the watts for each, and get the connected load, the peak demand, a generator size in kW and kVA, the amps and the 20 A circuits it represents.

Add Up Your Power Loads

Vendor booths

Booth lights, phone charging and a card reader.

Planning default 500 W. Use the nameplate figure.

Food vendor booths

Food warmers, a small fridge or a coffee maker. Running watts; compressors start higher.

Planning default 2,000 W. Use the nameplate figure.

Food trucks

Fryers, fridges, fans and lights. Many trucks bring their own generator.

Planning default 7,000 W. Use the nameplate figure.

Self-powered trucks are left out of the totals.

Small stages with PA

A small stage with a PA, mixer and a few stage lights.

Planning default 3,000 W. Use the nameplate figure.

Light towers or area lights

Per light tower or set of area lights. LED towers draw less than older lamps.

Planning default 1,000 W. Use the nameplate figure.

Info or registration tents

Laptops, a printer, phone charging and a light.

Planning default 500 W. Use the nameplate figure.

Other load

Anything else: a ride, a cooling tent, a charging station.

Running watts from the nameplate.

Sizing

Planning default 75%. Share of the load running at the same moment.

Default 25%, so the generator runs at about 80% or less.

Default 120 V, a standard US outlet.

35.2

Generator capacity (kW)

44 kVA at a 0.8 power factor, from a 28,125 W peak plus 25% headroom.

37,500 W

Connected load

Everything on your supply, at full draw.

28,125 W

Peak demand

Connected load times the 75% demand factor.

235 A

Amps at 120 V

Peak demand divided by the voltage, as one total.

20

20 A circuits

Connected load at 16 A a circuit. Food trucks need their own larger hookup.

The formula

37,500 W connected × 75% = 28,125 W peak.
28,125 W × 125% = 35,156 W, rounded up to 35.2 kW.
35.2 kW ÷ 0.8 power factor ≈ 44 kVA.

Sell power as a booth add-on and mark the power drops on your market map with vendor fair software.

Rough planning estimate, not an engineering figure. Check each vendor’s nameplate and starting watts. A licensed electrician and the generator rental company size the distribution, cabling, grounding and GFCI protection, and local fire and permit rules apply.

How the Event Power Calculator Works

  1. 1. List every load on your supply

    Count the vendor booths, food vendors, food trucks, stages, lights and tents that will plug into your power, not the ones bringing their own generator. Ask each vendor what they plug in on the application, and use the nameplate watts in place of the defaults.

  2. 2. Add up the connected load

    Multiply each count by its running watts and add them up. The defaults come to 37,500 W: everything that could be switched on.

  3. 3. Apply a demand factor

    Fridges cycle and chargers top off, so not every load peaks at once. At 75%, 37,500 W connected is a 28,125 W peak, about 235 A at 120 V. Use 100% if everything really runs together.

  4. 4. Add headroom for the generator

    Add 25% so the generator runs at about 80% of its rating or less: 28,125 W becomes 35.2 kW, or 44 kVA at a 0.8 power factor. Then give the rental company your list with the starting watts of every motor and compressor.

  5. 5. Hand it to the electrician

    The circuit count is a rough check on how much distribution you need. A licensed electrician and the rental company design the cable runs, distro boxes, grounding and GFCI protection, and your fire marshal and permit set the rules.

Write how much power each space includes, cord rules and generator rules into your vendor rules and regulations, place the power drops and generators when you plan your vendor market layout, and put generators, fuel and cable crossings in your event safety plan. The rest of the site plan is in the festival planning checklist, with the event tent size calculator and the portable toilet calculator. Booking trucks? See how to host a food truck event and the event permit guide.

Default Wattages Used by the Calculator

Rough running watts per unit, as starting points for planning. They are this calculator’s own defaults, not measured or published figures: equipment varies widely, so replace each one with the vendor’s nameplate figure.

Default running watts per load type in the event power calculator
LoadRunning watts eachTypically includes
Vendor booths500 WBooth lights, phone charging and a card reader.
Food vendor booths2,000 WFood warmers, a small fridge or a coffee maker. Running watts; compressors start higher.
Food trucks7,000 WFryers, fridges, fans and lights. Many trucks bring their own generator.
Small stages with PA3,000 WA small stage with a PA, mixer and a few stage lights.
Light towers or area lights1,000 WPer light tower or set of area lights. LED towers draw less than older lamps.
Info or registration tents500 WLaptops, a printer, phone charging and a light.

Watts on a 20 A Circuit

Watts are volts times amps. A 20 A circuit loaded to 16 A, the common 80% rule for loads that run for hours, carries about 1,920 W at 120 V. Several low-draw booths can often share one; a food booth with warmers and a fridge usually needs its own, and a food truck needs a larger dedicated connection. Your electrician decides how loads are split.

Starting Watts

Fridges, freezers, ice machines, air conditioners and other motors draw much more than their running watts for a moment when they start. Ask every vendor for their starting (surge) watts as well as running watts, and pass the list to the generator rental company.

What this assumes

Every figure the calculator starts with, and where it comes from. Where the honest answer is that a number depends on your venue, it says so rather than inventing one.

Watts per load
500 W for a vendor booth with lights, phone charging and a card reader; 2,000 W for a food vendor booth with warmers or a small fridge; 7,000 W for a food truck; 3,000 W for a small stage with a PA; 1,000 W for a light tower or set of area lights; 500 W for an info tent. These are this calculator's rough starting points, not measured or published figures. Replace each one with the vendor's own nameplate figure, which you can ask for on the vendor application.
Starting watts
Running watts only. Motors and compressors (fridges, freezers, ice machines, air conditioners, blenders) can draw several times their running watts for a moment when they start. The calculator does not add starting (surge) watts; ask each vendor for them and give the list to the rental company, which sizes the generator to handle the largest motors starting.
Self-powered food trucks
Many food trucks bring their own generator, and some markets require it. Switch the food trucks off your supply to leave them out of the totals. If some bring their own and some need yours, enter only the ones on your supply.
Demand factor
75% by default: lights, warmers and the PA run steadily, but fridges cycle, chargers top off and not every booth uses its full draw at the same moment. It is this calculator's planning default, not a code figure. Use 100% if everything runs flat out together, such as a stage with heavy lighting on a cold evening.
Headroom
25% by default, added on top of the peak demand so the generator runs at about 80% of its rating or less. Generators are not meant to run near 100% for hours, and the headroom also absorbs motor starts and vendors who plug in more than they declared. Ask your rental company what loading they recommend for the unit they supply.
kW and kVA
Generator ratings are commonly quoted in kVA at a 0.8 power factor, so kVA is the kW figure divided by 0.8. Check which figure, kW or kVA, and whether prime or standby, the rental quote uses.
Amps
Amps are the peak demand divided by the voltage, 120 V by default, as one total for planning. A real supply is usually 120/240 V single-phase or three-phase, which splits the current across legs; the electrician balances it.
20 A circuits
Counted from the connected load, not the peak, because a circuit has to carry whatever is plugged into it. Each 20 A circuit is loaded to 16 A (1,920 W at 120 V), the common 80% rule for continuous loads. It is an equivalent count: a food truck or a big cooking booth needs its own larger connection, often 30 A or 50 A, not several 20 A circuits.

What it does not model

  • Your local fire marshal, building or electrical inspector and event permit, which set the rules for generators, fuel, placement, cords and inspections.
  • Distribution: the cable runs, distro boxes, cable ramps, grounding and GFCI protection, which a licensed electrician designs and the rental company supplies.
  • Starting (surge) watts for motors and compressors, which the calculator leaves out.
  • Voltage drop on long cable runs to the far end of a site, which can need heavier cable or a second generator closer to the load.
  • Three-phase loads, 240 V cooking equipment and phase balancing.
  • Fuel: how long the generator runs on a tank at your load, and refueling during the event.
  • Noise and exhaust: where the generator can sit relative to booths, seating and neighbors.

Estimate only, from the figures you entered. Not a quote. Last reviewed October 2026.

See it on your own floor plan

Stop reading about it. Build one.

Upload the floor plan you already have and place your booths on it yourself, in Map D’s editor. Free to build, no contract, and nothing to install.

900+
Organizers who have run shows on Map D
9,000+
Events powered since 2011
1.8M+
Booths drawn to date

“I am really excited about this. The staff met with me this morning and we all LOVE the platform. People are already filling out their booths.”

· Director, International Trade and Development @ Maine Insurance Agents Association

Frequently asked questions

How big a generator do I need for an event?

Add up the running watts of everything that will be on it, multiply by a demand factor (this calculator uses 75%) for loads that do not all peak together, and add about 25% headroom so the generator is not running near full load. For 20 vendor booths at 500 W each and nothing else, that is 10,000 W connected, a 7,500 W peak and about 9.4 kW of generator, or 11.8 kVA. Then give the rental company the list of loads and their starting watts, because motors and compressors can need a bigger unit than the running total suggests.

How much power does a vendor booth need?

It depends on what the vendor plugs in, so ask on the vendor application and check the nameplate on each appliance. As rough planning starting points, this calculator uses 500 W for a booth with lights, phone charging and a card reader, and 2,000 W for a food booth with warmers or a fridge. A 20 A circuit at 120 V carries about 1,920 W continuously at the common 80% rule, so state in your vendor rules how much power each space includes and what vendors may plug in.

What is the difference between kW and kVA for a generator?

kW is the real power your loads use; kVA is the apparent power the generator has to supply, which includes the current motors and electronics draw without doing work. Generator ratings are commonly quoted in kVA at a 0.8 power factor, so 35.2 kW is about 44 kVA. When you compare quotes, check which figure each one uses, and whether it is a prime or standby rating.

Do food trucks need power from the organizer?

Many bring their own generator, and some events require it so the organizer's supply is not overloaded. Decide which it is before you book trucks, ask each truck for its power needs and plug type, and set rules for where truck generators may sit and how loud they may be. Your fire department may also have rules on generator placement and fuel.

Can I sell electricity to vendors with their booth?

Yes. In Map D you can set up booth types with their own prices, such as a food vendor space, and offer electricity as an add-on service with limited inventory, applying to certain booth types only, so vendors pick their space and order power at checkout. On the floor plan you can label power drops and generator locations with text labels or named areas. You can build the map for one event free; publishing it and selling booths and add-ons online need a paid plan. Map D does not size, supply or install power.